To synchronize other files required for your application (CSP files, images, documents, etc.) between the two servers that make up the mirror set follow one of the approaches:
Place those files on a shared disk by introducing a NAS or similar device
Or use file sync software to synchronize files between two servers.
I am converting xml message into HL7 message but the input XML message contains pdf which is converting into base 64 and getting mapped to OBX:5.5 in HL7 message and sending it to downstream
In Downstream service i am using normal HL7 TCP class EnsLib.HL7.Service.TCPService but the message looks like below i am not sure why stream is taking as another segment in HL7 message,
By default, the order of columns in a table is determined automatically by the system. To change the order, explicitly set the order for each property using the property keyword SqlColumnNumber when defining the class.
I have a business process that adds data to a global variable on receipt of an HL7 message, and a scheduled task that executes a class method defined within the same business process that removes data from the same global variable. With this in mind it makes sense to consider concurrency and therefore make use of the LOCK command.
My first question is whether this is actually necessary?
In a development environment, we have added quite a few presentation contexts to the DICOM configurations (the associations). We would need to find a way to export them from this environment to make it easier for us to import them in PRO (and avoid doing it by hand one by one).
I'm calling the expandAll() method to expand the whole tree structure but for some reason its only expanding the root folders but not all elements under those folders ?
var tree = zenPage.getComponentById( "MyTree"); tree.expandAll(true);
Is there anyway to delete a task if the namespace associated with task is already deleted?
We have a custom purge task which is associated with an old namespace( which is already deleted) . All the option in the task details are now disabled. Is there anyway to update it or delete it?
Could you help to search message details based on MRN in intersytems iris.
We have created 100+ interfaces and currenly in live (interystems cloud) . Now I try to search message details based on MRN using below query. it is working fine in DEV. but in prod it is taking ages.
I have been walking through this with a few team members and as such I thought there might be others out there who could use it, especially if you work with HL7 & Ensemble/HealthConnect/HealthShare and never venture out past the Interoperability section.
Given that Analyst property is defined as class object I'm getting the Analyst ID in the below dataBinding, but I'm looking to display the Analyst name, I tried using dataBinding="Analyst->Name" but no luck, I got the same issue when binding to dataCombo or comboBox ?
I have a BPL iterating over Dynamic arrays. Can I add Dynamic Array (%Dynamic Abstract Object) and also %Iterator.Array to BPL context? I tried and I see Error: %AddToSaveSet method does not exist for %Iterator.Array
I am experiencing an issue while executing a stored procedure in InterSystems Cache. Here’s the procedure I created
CREATE PROCEDURE Silk.sp_InsertRecord ( IN RecordDate TIMESTAMP, IN UserName VARCHAR(50), IN RecordType INT, IN RecordID VARCHAR(50), IN CategoryID INT, IN ApprovalDate TIMESTAMP, IN FileSize BIGINT, IN WorkstationName VARCHAR(50) ) BEGIN INSERT INTO DummyRecords ( RecordKey, FilePath, RecordDate, UserName,
We've just made a change to Server Manager with the aim of it coping better when a stored password is no longer valid, for example because it has been changed.
I've the below databinding on a combobox and the issue that the binding is coming with the display value of my levels so eg. I'm getting normal instead of 1 which mean the combobox in my form is not showing, so how get the binding to bring the VALUELIST rather then DISPLAYLIST ?
We see a lot of TCPIP connection error for few of the components not sure if it is a network glitch at the source/target or is it with us. And most of the times these errors are very transient and vanish on their own and the connection gets re established and the messages get processed. Here is the error we mostly see
ERROR <Ens>ErrTCPTerminatedReadTimeoutExpired: TCP Read timeout (30) expired waiting for terminator SegTerminatorAscii=13, on |TCP|50007|10620, data received =''
Since version 1.93 of VS Code, the “import and compile” process has been very slow (more than an hour). Have you encountered this issue and do you know how to resolve it?
I'm trying to make a connection to an external database using %SQLGatewayConnection, but the connection always fails. DSN properly configured. I try to make the same connection through isql in bash, and the connection is successful.
I try to add custom setting in BPL process by adding parameter SETTINGS = "Scope" and property Scope As %String. But how do I access instance property in BPL process? I get error that method or property Scope is not found.
When using InterSystems IRIS as an interoperability engine, we all know and love how easy it is to use the Message Viewer to review message traces and see exactly what's going on in your production. When a system is handling millions of messages per day, you may not know exactly where to begin your investigation though.
Over my years supporting IRIS productions, I often find myself investigating things like...